gantom-lighting-and-controls

POWERPAK PLUG-AND-PLAY

24VDC Power Supply

The PowerPak Plug and Play power supply is the perfecty way to inject power and DMX data into your Gantom Pro Cable system.  This power supply has an edison plug for easily connecting to a wall outlet.  It also has a male 5pin XLR connector for inputting a DMX control signal.  On the output side is a single female Gantom Pro Cable Trunk connector. The Gantom Pro Cable system bundles low voltage power and DMX signal into a single cable to minimize the amount of wiring required.

This power supply is capable of providing power to up to 32 of our 4.8W Gantom DMX fixtures. The maximum number of fixtures that can be powered on a system is dependent on the total length of cable in the system.  Please reference the Pro Cable system guidelines for more information.

FEATURES

  • Edison plug for connecting to power outlet
  • Power Input: 100-277VAC 47/63Hz
  • Power Output: Constant Voltage 24VDC 8.33A / 200W
  • Signal input: male XLR5 connector for DMX
  • Output Connector: Pro Cable Trunk Female Connector for Power/Signal
  • Durable metal housing
  • UL, CE, RoHS certified

PRODUCT DETAILS

Product

Part #

PP36

Item Description

PowerPak Plug and Play 24VDC

 

Output Specifications

DC Voltage

24VDC

Rated Current

8.33A

Current Range

0~8.33A

Rated Power

200W

Ripple & Noise (max)

150mV

Voltage Tolerance

plus/minus 0.5V

Setup Rise Time

80ms/110VAC, 220VAC

Hold Up Time (Typ.)

60ms/110VAC, 220VAC

Output Connector

Female Pro Cable Trunk connector

 

Input Specifications

Voltage Range

90~265VAC

Frequency Range

50~60Hz

Power Factor (Typ.)

>0.95@110VAC ; >0.98@220VAC

Efficiency (Typ.)

>91%

AC Current (Typ.)

.10A@110VAC; 1.01A@220VAC

Inrush Curent (Typ.)

COLD START 50A/110VAC, 220VAC

Power Input Connector

Edison Plug

DMX Input Connector

XLR5 Male Connector

 

Physical

Dimensions

245x70x48mm (L x W x H)

Weight

.7Kg (3.75lb)

Material

Metal Housing

 

Safety and EMC Specifications

Safety Standards

CE ETL Mark(EMC,LVD)

Withstand Voltage

I/P-O/P:3.0KVAC IP-GND:3.0KVAC

EMC Test Standards

EN55015:2006;

EN61547:1995+2000;

EN61000 -3-2:2006;

EN61000-3-3:1995+A2:2005;

EN61346-1:2001;

EN61347-2-13:2006

 

Environment Specifications

Working Temperature

-30~+55? (Refer to output load)

Working Environment

Meant for Indoor Installation

Storage Temperature, Humidity

-40~+80? ,10~99%RH

 

Protection Specifications

Short Circuit

Protection Type: recovers automatically after condition is removed

Overload

Overload protected@145-160% above peak reating

Over temperature

Protection Type: Shut down o/p voltage,re-power on to remove